• 1-Banner

Switchboard&Rack

  • 12kV Bypass Load Switch

    12kV Bypass Load Switch

    Specification:

    1. Voltage: 10KV

    2. Current: 400A

    3. Rated short-time withstand current: 20KA/4S

    4. Rated Active load breaking current: 400A

    5. Protection grade of switch body: IP68

    6. Application: The auxiliary components of the 10kv bypass non-power-off operation system are mainly used for the line opening and closing control of the operation system. Both sides are equipped with quick plug-in interfaces, which can be quickly connected with the self-locking quick plug-in type terminal of the bypass cable.

  • 630A Control Panel Cabinet

    630A Control Panel Cabinet

    Switchboard Specification:

    1. Voltage: 400V

    2. Current: 630A

    3. MCCB: ABB T5S630 630A

    4. Controller: ComAp IM1010

    5. Protection degree: IP55

    6. Application: Convert the direct current generated by the photovoltaic modules into alternating current that meets the requirements of the power grid, and control the stable connection between the photovoltaic system and the power grid to ensure the safe transmission of electrical energy to the grid.

  • Medium voltage switchboard

    Medium voltage switchboard

    Switchboard Specification:

    1. Voltage: 12KV

    2. Current: 630A

    3. Short-time withstand current: 20KA/4s

    4. Rated short-time withstand current(peak): 50KA

    5. Rated active load breaking current: 400A

    6. Protection grade: IP68

    7. Application: The auxiliary components of the 10kv bypass non-power-off operation system are mainly used for the line opening and closing control of the operation system. Both sides are equipped with quick plug-in interfaces, which can be quickly connected with the self-locking quick plug-in type terminal of the bypass cable.

  • Low voltage switchboard

    Low voltage switchboard

    Switchboard Specification:

    1. Voltage: 400V

    2. Current: 630A

    3. Short-time withstand current: 50KA

    4. MCCB: 630A (2 pcs)

    5. One incoming line with cable lug and one outgoing line with cable lug, two sets of panel sockets with 630A to meet one incoming line and one outgoing line for use

    6. Protection degree: IP55

    7. Application: widely used for power supply protection of special vehicles such as low-voltage power vehicles, especially suitable for emergency power supply for important power users and rapid power supply in urban residential areas. It can significantly save the preparation time for emergency power supply and improve the safety of power supply.

     

  • Low voltage switchboard

    Low voltage switchboard

    Switchboard Specification:

    1. Voltage: 400V

    2. Current: 630A

    3. Short-time withstand current: 50KA

    4. MCCB: 630A (2 pcs)

    5. One incoming line with cable lug and one outgoing line with cable lug, three sets of panel sockets with 630A to meet one incoming line and two outgoing lines for use

    6. Protection degree: IP55

    7. Application: widely used for power supply protection of special vehicles such as low-voltage power vehicles, especially suitable for emergency power supply for important power users and rapid power supply in urban residential areas. It can significantly save the preparation time for emergency power supply and improve the safety of power supply.

  • Low voltage switchboard

    Low voltage switchboard

    Switchboard Specification:

    1. Voltage: 400V

    2. Current: 630A

    3. Short-time withstand current: 50KA

    4. MCCB: 630A

    5. Four sets of panel sockets with 630A to meet one incoming line and three outgoing lines for use

    6. Protection degree: IP55

    7. Application: widely used for power supply protection of special vehicles such as low-voltage power vehicles, especially suitable for emergency power supply for important power users and rapid power supply in urban residential areas. It can significantly save the preparation time for emergency power supply and improve the safety of power supply.

  • Low voltage switchboard

    Low voltage switchboard

    Switchboard Specification:

    1. Voltage: 400V

    2. Current: 630A

    3. Short-time withstand current: 50KA

    4. MCCB: 630A

    5. Two sets of panel sockets with 630A, left are input sockets, right are output sockets

    6. Protection degree: IP55

    7. Application: widely used for power supply protection of special vehicles such as low-voltage power vehicles, especially suitable for emergency power supply for important power users and rapid power supply in urban residential areas. It can significantly save the preparation time for emergency power supply and improve the safety of power supply.

     

  • 2500A Outdoor Power Distribution Cabinet

    2500A Outdoor Power Distribution Cabinet

    Switchboard Specification:

    1. Voltage: 415V/240 VAC

    2. Current: 2500A, 3 Phase, 50/60 Hz

    3. SCCR: 65KAIC

    4. Cabinet material: SGCC

    5. Enclosure: NEMA 3R outdoor

    6. Main MCCB: Noark 3P/2500A 1PCS

    7. MCCB: Noark 3P/250A 10PCS&3P/125A 1PCS

    8. 3 Phase muti-function power meter