Switchboards · Racks · PDUs · Industrial Plugs · Power Cords | Built for AI/HPC Density
The Problem with Fragmented Procurement
Five suppliers across three countries. Mismatched interfaces. Inconsistent lead times. On-site rework. This is how data center projects fall behind schedule and over budget.
ANEN Power delivers the full power chain — main switchboard → row cabinet → rack → PDU → industrial plug → power cord. One vendor. One standard. One BOM. From primary distribution to rack-level connection, all integrated.
The Complete Product Chain: Every Link Verified
① Switchboards / Distribution Cabinets
- Main input 800A–4000A, 415Y/240V, 3P+N+PE
- 100% full-capacity neutral bus, designed for nonlinear IT loads
- IEC/EN 61439 design verification: short-circuit, temperature rise, protective conductor
- Integrated multifunction meter (Modbus TCP/SNMP/Redfish)
- Full-capacity neutral bus + separate equipment-ground bus, clearly labeled
② Racks
- Standard 19-inch, compatible with 42U/48U/52U cabinets
- High-density structural design, supports 30–150kW per rack
- Front/rear service access, ample cable management space
- Fully compatible with 0U vertical PDU mounting
③ Smart PDUs
- 18/24/36/42/48/60-outlet C39 combination outlets, accepts C13/C15/C19/C21
- 32A/63A/125A three-phase input, built for GPU/AI high-density racks
- Outlet-level metering + remote switching
- PDU input and phase-level (L1/L2/L3) metering
- Local LCD display for real-time voltage, current, power
- Communications: HTTP/HTTPS, SNMP, Modbus TCP, Redfish API
- 0U vertical mount, total length ≤2000mm, fits 42U/48U/52U cabinets
- Full load at 40°C ambient, derating curve above 40°C provided
④ Industrial Plugs / Receptacles
- IEC 60309 standard, 125A, 415V, 5-pin (3P+N+PE), 6h
- IP67 rated, dust and water resistant
- Panel-mounted, factory wired
- Fully matched to switchboard and PDU input
⑤ Power Cords / Cable whips
- Custom lengths: based on practical applications
- High-current rating, compatible with 125A input
- Fully compatible with PDU and switchboard interfaces
Why ANEN Power?
- End-to-end coverage — from primary distribution to rack-level connection
- High-density ready — supports 30–150kW per rack for GPU/AI clusters
- Certified quality — UL / CE, built for Tier III/IV projects
- Fast delivery — 25–35 days bulk lead time, far faster than industry average (20+ weeks)
- Custom engineering — OEM/ODM to your exact specifications
- Full traceability — MEC production tracking from assembly to test
- Proven by industry leaders — long-term OEM partner to EATON, Delta and Huawei; volume deployments verified in North American AI data centers
Applications
- AI training and inference data centers
- Hyperscale cloud data centers
- HPC clusters
- Colocation and wholesale data centers
- Edge computing nodes
- Modular / containerized data centers