PDUs
-
SA2-30 12 Ports Basic PDU
SA2-30 Specifications:
1. Input voltage: 3-phase 346-415 VAC
2. Input current: 3 x 80A
3. Output voltage: single-phase 200-240VAC
4. Outlet: 12 ports of SA2-30 sockets
5. Each port has 1P 20A circuit breaker
-
L7-20R 18 Ports Smart PDU
L7-20R Specifications:
1. Input Voltage: three-phase 346-480V
2. Input Current: 3 x 125A
3. Output voltage: single-phase 200-277V
4. Outlet: 18 ports of L7-20R sockets
5. Each port has 1P 20A circuit breaker
6. Remote monitor and control ON/OFF of each port
7. Remote monitor input current, voltage, power, power factor, KWH
8. Onboard LCD display with menu control
9. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
-
L16-30R 10 Ports Basic PDU – Receptacles face downward
L16-30R Specifications:
1. Input voltage: 3-phase 346-480VAC
2. Input current: 3 x 250A
3. Output voltage: 3-phase 346-480 VAC
4. Outlet: 10 ports of L16-30R Sockets
5. Each port has Noark UL489 3P 30A circuit breaker
-
HPC 24 Ports C39 SMART PDU – 60A
HPC C39 Specifications:
1. Input: 346~415V, 3 x 60A
2. Output: 200~240VAC
3. Outlets: 24 ports of C39 sockets with self-locking feature, compatible with C13 and C19
4. Output phase rotation ABCABC in black, red, blue
5. Protection: each TWO ports have 1P 20A UL489 hydraulic magnetic circuit breaker
6. Remote monitor PDU input and each port current voltage, power, KWH
7. Smart meter with Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
8. Onboard LCD display with menu control and local monitoring
9. Ambient temperature up to 60°C
10. Input cable 5*6AWG, 3 meters
-
PA45 28 PORTS SMART PDU
PDU Specifications:
1. Input Voltage: three-phase 346-480V
2. Input Current: 4*400A
3. Output voltage: 3-phase 346-480V or single-phase 200-277V
4. Outlet: 28 ports of 6-pin P34 sockets
5. PDU is compatible with T21 and S21 miners
6. Each port has Noark 3P 30A B1H3C30 circuit breaker
7. Sockets and circuit breakers can be serviced without opening front cover
8. Onboard LCD display with menu control
9. Ethernet/RS485 interface, support HTTP/SNMPISSH2/MODBUS/CA
10. Internal fan with LED indicator
11. Dual input lugs (YA272N type) on the front and back of busbar and through bolted
-
PA45 21 PORTS SMART PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 150A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200-277 VAC
4. Outlet: 21 ports of 6-pin P34 sockets
5. PDU is compatible with T21 and S21 miners
6. Each port has 3P 25A circuit breaker
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input and each port’s current, voltage, power, power factor, KWH
9. Onboard LCD display with menu control
10. Ethernet/RS485/USB interface, support HTTP/SNMP/SSH2/MODBUS/CA
11. Sockets can be replaced without opening PDU top cover
12. PDU can be connected to plug and play temp/humidity or other sensors via USB
-
PA45 36 Ports Smart PDU with main breaker
PDU Specifications:
1. Input voltage: 3-phase 346-480 V
2. Input current: 3 x 250A
3. Output voltage: 3-phase 346-480 V or single-phase 200-277 V
4. Outlet: 36 ports of 6-pin P34 sockets
5. Integrated 250A main circuit breaker
6. Each port has 3P 25A circuit breaker
7. PDU is compatible with T21 and S21 miners
8. Remote monitor and control ON/OFF of each port
9. Remote monitor input and each port’s current, voltage, power, power factor, KWH
10. Onboard LCD display with menu control
11. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS/CA
12. Internal fan with LED indicator
-
PA45 18 PORTS SMART PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 150A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200-277 VAC
4. Outlet: 18 ports of 6-pin PA45 sockets
5. Each port has 3P 20A circuit breaker
6. PDU is compatible with T21 and S21 miners
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input current, voltage, power, power factor, KWH
9. Onboard LCD display with menu control
10. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
11. Internal fan with LED indicator
-
36 PORTS PA45 BASIC PDU – ETL Certified
PDU Specifications:
1. Input Voltage: three-phase 380-480V
2. Input Current: 3 x 350A
3. Output voltage: 3-phase 380-480V or single-phase 220-277V
4. Outlet: 36 ports of 6-pin P34 Sockets organized in alternating phase order
5. PDU is compatible with T21 and S21 miners
6. Each Noark 3P 30A B1H3C30 circuit breaker controls 3 sockets
-
PA45 12 PORTS BASIC PDU with main breaker for Antbox
PDU Specifications:
1. Input voltage: three-phase 346-480 V
2. Input current: 3 x 125A
3. Output voltage: three-phase 346-480 V or single-phase 200~277 V
4. Outlet: 12 ports of 6-pin P34 sockets, 1 port P14 socket
5. PDU is compatible with T21 and S21 miners
6. 3P 125A UL489 Hydraulic Magnetic main circuit breaker
7. Three-phase imbalance alarm display
-
PA45 12 PORTS BASIC PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 V
2. Input current: 3 x 125A
3. Output voltage: 3-phase 346-480 V or single-phase 200-277 V
4. Outlet: 12 ports of 6-pin P34 sockets
5. PDU is compatible with T21 and S21 miners
6. Each port has 3P 25A circuit breaker
7. LED indicator for each port
8. Cable entry hole can have dustproof brushes or cable gland
-
9 PORTS C19 BASIC PDU
PDU Specifications:
1. Input Voltage: three phase 346~415V
2. Input Current: 3*60A
3. Output Voltage: single-phase 200~240 VAC
4. Outlet: 9 ports of C19 sockets organized in three sections
5. Each 1P 60A Circuit Breaker controls 3 port C19 sockets
6. One port C13 for networ