• Anderson power connectors and power cables

Mining&HPC Data center PDU

  • 12 Ports C19 Mining PDU

    12 Ports C19 Mining PDU

    PDU Specifications:

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3 x 80A

    3. Output voltage: single-phase 200~277 VAC

    4. Outlet: 12 ports of C19 Sockets

    5. Each port has 1P 20A Circuit Breaker

  • 18 Ports SA2-30 Mining PDU

    18 Ports SA2-30 Mining PDU

    PDU Specifications:

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3 x 200A 3. Output voltage:3-phase 346-480 VAC

    4. Outlet: 18 ports of 3-phase SA2-30 Sockets, 2 C13 sockets

    5. Each port has 3P 20A Circuit Breaker

     

  • 26 Ports L16-30R Smart PDU

    26 Ports L16-30R Smart PDU

    PDU Specifications:

    1. Input voltage: three-phase 346-415VAC

    2. Input current: 3 x 200A

    3. Integrated 250A LS MCCB

    4. Output Current: three phase 346-415VAC

    5. Output receptacles: 26 ports L16-30R and 1 port C13

    6. Each L16-30R port has UL489 3P 20A hydraulic magnetic circuit breaker, C13 port has 1P 2A hydraulic magnetic circuit breaker

    7. Each output has corresponding network interface

    8. Remote monitor PDU input and each port current, voltage, power, KWH

    9. Remote control on/off of each port

     

  • 24 Ports C19 PDU with Network Switch

    24 Ports C19 PDU with Network Switch

    PDU Specifications:

    1. Shell Material: 1.2 SGCC   Color: Black powder

    2. Input Voltage: 380-433Vac, WYE, 3N, 50/60 HZ

    3. Output Voltage: 220-250Vac

    4. Max. Current: 160A

    5. Output socket: 24 ports C19  Rated 250V/20A

    6. Control and protection method: Each four 80A liquid magnetism Breaker

    7. Internal wire: Main wire 2*5AWG, Branch line 12AWG

  • 18 Ports L7-30R Mining PDU

    18 Ports L7-30R Mining PDU

    PDU Specifications:

    1. Input voltage: three-phase 346-480VAC

    2. Input current: 3 x 200A

    3. Integrated 200A Fuse for three-phase

    4. Output Current: single phase 200-277VAC

    5. Output receptacles: 18 ports L7-30R

    6. Each port has UL489 1P 32A hydraulic magnetic circuit breaker

    7. Each three-port set can be serviced without removing PDU cover

    8. Internal venting fan with 1P/2A circuit breaker

  • 10 ports L16-30R mining PDU

    10 ports L16-30R mining PDU

    PDU Specifications:

    1. Input voltage: 3-phase 346-480VAC

    2. Input current: 3 x 250A

    3. Output voltage: 3-phase 346-480 VAC

    4. Outlet: 10 ports of L16-30R Sockets

    5. Each port has 3P 30A Circuit Breaker

  • HPC 24 Ports C39 Smart PDU

    HPC 24 Ports C39 Smart PDU

    PDU Specifications:

    1. Input voltage: 346-415V

    2. Input current: 3*60A

    3. Output voltage: 200-240V

    4. Outlets: 24 ports of C39 sockets with self-locking feature

    Socket compatible to both C13 and C19

    5. Protection: 12pcs of 1P20A UL489 circuit breakers

    One breaker for every two outlets

    7. Remote monitor PDU input and each port current, voltage, power, KWH

    8. Remote control on/off of each port

    9. Smart Meter with Ethernet/RS485 ports, support HTTP/SNMP/SSH2/MODBUS

  • 36 ports PA45 basic PDU

    36 ports PA45 basic PDU

    PDU Specifications

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3*350A

    3. Output voltage: 3-phase 346-480 VAC or single-phase 200-277 VAC

    4. Outlet: 36 ports of 6-pin PA45 Sockets organized in alternating phase order

    5. PDU is compatible for 3-phase T21 and single-phase S21

    6. Each 3P 30A Circuit Breaker controls 3 sockets and one 3P 30A breaker for Fan

    7. Integrated 350A main circuit breaker

  • 24 ports P34 basic PDU for cryptomining

    24 ports P34 basic PDU for cryptomining

    PDU Specifications:

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3x200A

    3. Output voltage: 3-phase 346-480  VAC or single-phase 200-277 VAC

    4. Outlet: 24 ports of 6-pin PA45 Sockets organized in three sections

    5. PDU is compatible for 3-phase T21 and single-phase S21

    6. Each port has 3p 25A Circuit Breaker

    7. LED indicator for each port

  • 28 ports P34 basic PDU for mining

    28 ports P34 basic PDU for mining

    PDU Specifications: 1. Input Voltage: three phase 346-480V 2. Input Current: 3*400A 3. Output voltage: 3-phase 346-480V or single-phase 200-277V 4. Outlet: 28 ports of 6-pin PA45 Sockets(P34) organized in three sections 5. PDU is compatible for 3-phase T21 and single-phase S21 6. Each port has Noark 3P 20A B1H3C20 circuit breaker
  • 12 ports P34 basic PDU

    12 ports P34 basic PDU

    PDU Specifications:

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3x125A

    3. Output voltage: 3-phase 346-480 VAC or single-phase 200-277 VAC

    4. Outlet: 24 ports of 6-pin PA45 Sockets organized in three sections

    5. PDU is compatible for 3-phase T21 and single-phase S21

    6. Each port has 3P 25A circuit breaker

    7. LED indicator for each port

  • 12 ports P34 Smart PDU for S21 T21 miner

    12 ports P34 Smart PDU for S21 T21 miner

    PDU Specifications:

    1. Input voltage: 3-phase 346-480 VAC

    2. Input current: 3x125A

    3. Output voltage: 3-phase 346-480 VAC or single-phase 200-277 VAC

    4. Outlet: 12 ports 6-pin PA45 Sockets organized in three sections

    5. Eaton port has 3p 25A circuit breaker

    6. PDU is compatible for 3-phase T21 and single-phase S21

    7. Remote monitor and control ON/OFF of each port

    8. Remote monitor input and end each port’s current, voltage, power, power factor, KWH

    9. Onboard LCD display with menu control

    10. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS/CA

    11. PDU cover middle section can be removed to service sockets

    12. PDU can be connected to plug and play temp/humidity sensors

    13. Internal venting fan with satus LED indicator

     

12 Next > >> Page 1 / 2