Crypto Mining
-
18 PORTS C19 PDU
PDU Specifications:
1. Input voltage: 3-phase 346-415VAC
2. Input current: 3 x125A
3. Output voltage: single-phase 200~240 VAC
4. Outlet: 18 ports of C19 sockets with locking feature organized in three sections
5. 3P 125A UL489 Hydraulic Magnetic main circuit breaker
6. Each port has 1P 20A UL489 Hydraulic Magnetic circuit breaker
-
18 PORTS C13 PDU
PDU Specification:
1. Input Voltage: three phase 346~415V
2. Input Current: 3*100A
3. Output voltage: single-phase 200~240V
4. Outlet: 18 ports of C13 Sockets organized in three sections
5. 9×32A 1P breakers,every Circuit Breaker control 2 sockets
6. One port C13 for network, with 1P/2A breake
-
6 PORTS C19 SMART PDU
PDU Specifications
1. Input Voltage: three phase 346~400V
2. Input Current: 3*32A
3. Output voltage: single-phase 200~230V
4. Outlet: 6 port C19 sockets, organized in three sections
5. Each port has 1P 20A UL489 circuit breaker
6. Smart meter module with onboard LCD display and menu control
7. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
8. Remote monitor and control ON/OFF of each port
9. Remote monitor input and per port current, voltage, power, power factor, KWH
10. Rack-mounted installation, applied in data center
-
HPC 36 PORTS C39 SMART PDU
PDU Specifications
1.Input voltage: 346-415VAC
2. Input current: 3 x 60A
3. Output voltage: 200~240VAC
4. Outlets: 36 ports of C39 sockets with self-locking feature Socket compatible to both C13 and C19
5. Outlets arranged in alternating phase sequence in black, red, blue color
6. Protection: 12 pcs of 1P 20A UL489 hydraulic magnetic circuit breakers One breaker every three outlets
7. Remote monitor PDU input current, voltage, power, KWH
8. Remote monitor each output port’s current, voltage, power, KWH
9. Smart Meter with Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
10. Onboard LCD display with menu control and local monitoring
11. Operating environment temperature 0~60C
12. UL/cUL Listed and Certified (ETL Mark)
13. The input terminal has a 5 X 6 AWG line 3 meter
-
HPC 24 PORTS C39 SMART PDU
PDU Specifications:
1. Input voltage: 346-415V
2. Input current: 3*125A
3. Output voltage: 200-240V
4. Outlets: 24 ports of C39 sockets with self-locking feature Socket compatible to both C13 and C19
5. Protection: 24pcs of 1P20A UL489 circuit breakers One breaker for every one outlet
7. Remote monitor PDU input and each port current, voltage, power, KWH
8. Remote monitor each output port’s current, voltage, power, KWH
9. Smart Meter with Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
10. UL/cUL Listed and Certified
-
Power cable for SA2-30 TO M25 plug
SA2-30 TO M25 Single phase Power Cable:
ANEN SA2-30 power connector, rated 50A,600V, UL certified;
M25 self-locking plug, rated 40A, 300V with IP67 grade;
Application: connection between M64 hydro cooling miner and PDUwith SA2-30 socket.
-
18 Ports P34 Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 150A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200~277 VAC
4. Outlet: 18 ports of 6-pin PA45 Sockets organized in three sections
5. Each port has 3P 20A Circuit Breaker(3P 16A/25A optional)
6. PDU is compatible for 3-phase T21 and single-phase S21
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input current, voltage, power, power factor, KWH
9. Onboard LCD display with menu control
10. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
11. Internal fan with LED indicator
-
3 Ports P34 Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 30A
3. Input cable: L22-30P plug with UL ST 10AWG 5/C 6FT cable
4. Output voltage: 3-phase 346-480 VAC or single-phase 200~277 VAC
5. Outlet: 3 ports of 6-pin PA45 (P34), 3-phase/single-phase compatible
6. Integrated 3P 30A main circuit breaker
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input & per port current, voltage, power, PF, KWH
9. Smart Meter with Ethernet/RS485 interface, support http/snmp/ssh2/modbus
10. Onboard LCD display with menu control and local monitoring
-
30 Ports P34 Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 250A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200~277 VAC
4. Outlet: 30 ports of 6-pin PA45 Sockets organized in three sections
5. Each port has 3P 30A UL489 Circuit Breaker
6. PDU is compatible for 3-phase T21 and single-phase S21
7. Remote monitor input current, voltage, power, power factor, KWH
8. Onboard LCD display with menu control
9. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
10. Internal venting fan with status LED indicator
-
16 Ports L7-20R Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 200A
3. Output voltage: single-phase 200~277 VAC
4. Outlet: 16 ports of L7-20R Sockets
5. Each port has 1P 25A Circuit Breaker
6. Remote monitor input current, voltage, power, power factor, KWH
7. Onboard LCD display with menu control
8. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
-
24 Ports P34 Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 200A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200~277 VAC
4. Outlet: 24 ports of 6-pin PA45 Sockets organized in three sections
5. Each 3P 25A Circuit Breaker controls 3 sockets
6. PDU is compatible for 3-phase T21 and single-phase S21
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input current, voltage, power, power factor, KWH
9. Onboard LCD display with menu control
10. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
11. Internal fan with LED indicator
-
16 Ports P34 Smart PDU
PDU Specifications:
1. Input voltage: 3-phase 346-480 VAC
2. Input current: 3 x 300A
3. Output voltage: 3-phase 346-480 VAC or single-phase 200~277 VAC
4. Outlet: 16 ports of 6-pin PA45 Sockets organized in three sections
5. Each port has 3P 25A Circuit Breaker
6. PDU is compatible for 3-phase T21 and single-phase S21
7. Remote monitor and control ON/OFF of each port
8. Remote monitor input current, voltage, power, power factor, KWH
9. Onboard LCD display with menu control
10. Ethernet/RS485 interface, support HTTP/SNMP/SSH2/MODBUS
11. Internal fan with LED indicator